Competitiveness of Kwang Sung

Comparative Table for SCR System between other companies and Kwangsung

 Other CompaniesKwangsung
CFD Flow AnalysisOutsourcingOK
Detail DesignOutsourcingOK
Test LabDon't HaveHave
Min. Emission Gas Temp'Over 300°COver 200°C
AnalyzerProcurement ItemOwn System
Operative TypePLCPCB
ManufacturingOutsourcingHave Own Fabrication & Paint Shop

KwangSung Can Do A to Z! with Fast & Low Price! KwangSung could provide one stop solution (Analysis, Design, manufacturing, installation, maintenance). If you want to get more detail information, then feel free contact us.

SCR System CFD Analysis

Setup Condition – SCR inlet

 ItemUnit


Flue gas Flow Rate
10³m³N/h-wet3110
cc/min24383.73
kg/s0.4063955
Temp.°C365
O2Vol%-dry2.64
H2OVol%-wet11.23
CO2Vol%-dry16.41
N2Vol%-dry80.9

Interpretation Result – SCR outlet

Inlet Result (NOx), ppm180
Outlet Result (NOx), ppm24
Reduction Ratio (NOx), %86
Inlet Result (Slip NH3), ppm350
Outlet Result (Slip NH3), ppm0

Pressure Distribution Chart

NOx Distribution Chart

NH3 Distribution Chart

SCR System Structure Analysis I

SCR Sub Structure deformation

SCR Sub Structure bending moment deformation

SCR System Structure Analysis II

SCR Sub Structure drawing for Sharing

SCR Sub Structure drawing for Axle line

Login