Global leading SCR system manufacturer and Kwangsung made a lot of successful story. Please find our portfolio.

NOx Regulation in the world

NOx Regulation in the world

U.S. / Canada ECAs

NOx Regulation in the world
Cover areas within 200 nautical miles from land and become effective on 1st, Aug, 2012.

Tier II NOx Regulation enforced from 1st, Jan, 2011 and Tier III NOx regulation will enforce from 2016.

Engine Speed (rpm) Tier I (~ year 2010) Tier II (Year 2011~ Year 2015) Tier III (~Year 2016)
Under 130 rpm 17.0 g/kwh 14.4 g/kwh (15% Reduction Contrast Tier 1) 3.4 g/kwh (80% Reduction Contrast Tier 1)
130 ~ 2,000 rpm 45.n ̄º·²³ g/kwh 44.0 ̄º·²³ g/kwh (15.5% ~ 21.8% Reduction Contrast Tier 1) 9.0 ̄º·²³ g/kwh (80% Reduction Contrast Tier 1)
Over 2,000 rpm 9.8 g/kwh 7.7 g/kwh (21.8% Reduction Contrast Tier 1) 2.0 g/kwh (80% Reduction Contrast Tier 1)
NOx-regulation-chart

NOx Regulation in the world

Sulfur dioxide (also sulphur dioxide) is the chemical compound with the formula SO2. At standard atmosphere, it is a toxic gas with a pungent, irritating, and rotten smell. The triple point is 197.69 K and 1.67kPa. It is released naturally by volcanic activity.

Inhaling sulfur dioxide is associated with increased respiratory symptoms and disease, difficulty in breathing, and premature death. In 2008, the American Conference of Governmental Industrial Hygienists reduced the short-term exposure limit to 5 parts per million (ppm)

Comparative Table for SCR System between other companies and Kwangsung

Other Companies Kwangsung
CFD Flow Analysis Outsourcing OK
Detail Design Outsourcing OK
Test Lab Don't Have Have
Min. Emission Gas Temp' Over 300°C Over 200°C
Analyzer Procurement Item Own System
Operative Type PLC PCB
Manufacturing Outsourcing Have Own Fabrication & Paint Shop

Application for Marine

Certificates & Reliability

Certificate of KR Type Approval (Reliability Test)

  • Satisfied Lower than NOx 15 ppm, NH3 Slip 10 ppm by using LNG, MDO, HFO in Load Rate of 100%, 88%, 40% of 3 t/h Boiler
  • Automatic Controller Durability Test Accepted
  • Catalyst Durability Tested 8,000hrs
Type-Approval-Certificate
Type APPROVAL CERTIFICATE
Reliability-Test
Reliable test 1
Reliability-Test
Reliability-Test

Application for Plant

Application for SCR System CFD Analysis

Setup Condition – SCR inlet

Item Unit
Flue gas Flow Rate 10³m³N/h-wet 3110
cc/min 24383.73
kg/s 0.4063955
Temp. °C 365
O2 Vol%-dry 2.64
H2O Vol%-wet 11.23
CO2 Vol%-dry 16.41
N2 Vol%-dry 80.9

Interpretation Result – SCR outlet

Inlet Result (NOx), ppm 180
Outlet Result (NOx), ppm 24
Reduction Ratio (NOx), % 86
Inlet Result (Slip NH3), ppm 350
Outlet Result (Slip NH3), ppm 0

NOx Distribution Chart

NOx-Distribution-Chart

Pressure Distribution Chart

NH3-Distribution-Chart

NH3 Distribution Chart

SCR-CFD

Application for SCR System Structure Analysis I

SCR-Sub-Structure-deformation

SCR Sub Structure deformation

SCR-Sub-Structure-bending-moment-deformation

SCR Sub Structure bending moment deformation

Application for SCR System Structure Analysis II

SCR Sub Structure drawing for Sharing

SCR Sub Structure drawing for Axle line

SCR-Sub-Structure-drawing-for-Axle-line

Patents

No Namek Nation Reg. Date Reg. No
1 SCR System
(Urea Injection)
KOR 2010.03.17 10-0949382
2 SCR System
(Urea+Air Injection)
KOR 2010.03.17 10-0949383
3 SCR System with By-Pass
(Emission through By-pass Pipe in Emergency)
KOR
CHN
JPN
USA
EU
2010.03.30 10-0951440
4 DUST Proof SCR System KOR 2010.04.13 10-0953951
5 SCR System
(Water Injection)
KOR 2010.06.10 10-0958345
6 Marine & Plant SCR System
(SCR + DPF)
KOR 2010.09.24 10-0984547
7 Marine & Plant SCR System
(Monitoring System)
KOR 2010.09.24 10-0984548
8 Marine & Plant SCR System
(Automatic Control System)
KOR 2012.09.06 10-1182253

Portfolio of installation

marineoffshore-performance1

Marine & Offshore Performance (1)

Read More
marineoffshore-performance2

Marine & Offshore Performance (2)

Read More
SCR-Still-Mill-1

Steel Mill (1)

Read More
SCR-Still-Mill-2

Steel Mill (2)

Read More
SCR-Still-Mill-3

Steel Mill (3)

Read More
Lifting-of-OUTLET-DUCT

Lifting of OUTLET DUCT

Read More
Ready-for-lifting-of-OUTLET-DUCT

Ready for lifting of OUTLET DUCT

Read More
Ready-for-lifting-of-B_BLOCK-OUTLET-DUCT

Ready for lifting of B BLOCK OUTLET DUCT

Read More
Installation-Complete-of-OUTLET-DUCT-A_B-BLOCK

Installation Complete of OUTLET DUCT A/B BLOCK

Read More
Rotation-for-Lifting-of-1-BLOCK-HOPPER-1

Rotation for Lifting of #1 BLOCK HOPPER

Read More
Rotation-for-Lifting-of-1-BLOCK-HOPPER-2

Rotation for Lifting of #1 BLOCK HOPPER

Read More
Stand-Straight-for-Lifting-of-1-BLOCK-HOPPER

Stand Straight for Lifting of #1 BLOCK HOPPER

Read More
Lifting-of-1-BLOCK-HOPPER

Lifting of #1 BLOCK HOPPER

Read More
Installation-Complete-of-1-BLOCK-HOPPER-1

Installation Complete of #1 BLOCK HOPPER

Read More
Installation-Complete-of-1-BLOCK-HOPPER-3

Installation Complete of #1 BLOCK HOPPER

Read More
Ready-for-Installation-of-2-BLOCK

Ready for Installation of INLET DUCT #2 BLOCK

Read More
Installation-of-INLET-DUCT-1-BLOCK-1

Installation of INLET DUCT #1 BLOCK

Read More
Installation-of-INLET-DUCT-1-BLOCK-2

Installation of INLET DUCT #1 BLOCK

Read More

FAQ

Most frequent questions and answers

Yes you can edit every single element.

Yes, these files are fully layered.

Click on the mask and click “B” for brush tool.

You will need Photoshop preferably version CS6 and newer.

happy holidays

we want to hear from you